<article-title>Assessing Thermal Comfort in Relation to Building Designs: Case Study of Naturally Ventilated Studio Classrooms in a Warm and Humid Uli, Nigeria</article-title>
</title-group>

<author>Charles Munonye<sup>1</sup> and Oluchi Ifebi<sup>2</sup></author>

<aff><sup>1</sup>University of Salford, United Kingdom</aff>
<aff><sup>2</sup>Chukwuemeka Odumegwu Ojukwu University, Nigeria</aff>

</article-meta></front>
<body>
<abstract>
<title>ABSTRACT</title>
<p>Low-energy buildings have been the goal of sustainable building advocates in this era of global action
on climate change mitigation strategies for which the building stock is a high contributor of greenhouse
gas emission. An appropriate building design that is thermally acceptable to building occupants is one
of the strategies of achieving low-energy buildings, especially in the tropics, since it will discourage the
use of active ventilators to achieve thermal comfort. In spite of this importance of an appropriate
building design, there is little information available about the thermal comfort perception of building
occupants as they relate to the various building characteristics. This paper presents the findings of the
subjective assessment of students&#39; responses to the thermal conditions in two typical university
buildings in a warm and humid climate of Uli, Nigeria; enclosed and open-plan studio classrooms,
using survey questionnaires. The aim was to determine the students&#39; thermal sensation, thermal
preference, thermal acceptability and to compare the thermal conditions in both categories of buildings.
The results showed that none of the classrooms examined met the 80% criterion specified by ASHRAE
Standard 55 for a comfortable indoor environment using the seven - point ASHRAE thermal sensation
assessment scale. However, more respondents were satisfied with the indoor thermal environment in the
open classroom than in the enclosed classroom having voted 74% and 31%, respectively, with 82%
acceptance rate in the open studio classroom, confirming that building designs have an influence on the
indoor thermal conditions. The results will serve as a guide to architects and other professionals in the
building industry.</p>
<p><italic>Keywords: </italic>Subjective, Low-energy building, Naturally ventilated, Studio classrooms, Thermal
comfort.</p>